SOLENOID VALVES

FEATURES

  • Two way shut-off valves for the control air, inert gas, water, oil and other gases/liquids compatible with the sealing material usedvan khí nén
  • Valves do not require a minimum operating pressure
  • All products are covered by Pressure Equipment Directive 97/23/EC and are suitable for group 1 and 2 fluids
  • The solenoid valves satisfy all relevant EC di b96 rectives

GENERAL `
Differential pressure            See «SPECIFICATIONS»  [1 bar =100 kPa]
Maximum viscosity              65 cSt (mm2/s)
Response time                     15 – 120 ms

fluids (*)temperature range (TS)seal materials (*)
air, inert gas, water, oil-20°C to +85°CNBR (nitrile)

MATERIALS IN CONTACT WITH FLUID

(*)  Ensure that the compatibility of the fluids in contact with the materials is verified

Brass bodyStainless steel body
BodyBrassAISI 304 SS
Core tubeStainless steelStainless steel
Core and plugnutStainless steelStainless steel
SpringsStainless steelStainless steel
SeatBrassStainless steel
Seals, diaphragm & discNBRNBR
Disc holder (NO function)PAPA
Shading coilCopperSilver

ELECTRICAL CHARACTERISTICS

Coil insulation class                       F or H
Connector                                        Spade plug  (cable Ø 6-10 mm)
Connector specification                 ISO 4400 / EN 175301-803, form A
Electrical safety                               IEC 335
Electrical enclosure protection      Moulded IP65 (EN 60529)
Standard voltages                           DC (=) : 24V – 48V
(Other voltages and 60 Hz on request)      AC (~) : 24V – 48V – 115V – 230V / 50 Hz

 

prefix option

power ratingsoperator ambient temperature range  (TS)replacement coil 

type (1)

inrush

~

holding

~

hot/cold

=

~=
(VA)(VA)(W)(W)(C°)230 V/50 Hz24 V DC
 

SC

5

78

110

240

23

35

33,6

43

10,5

16,7

15,4

20

9/ 11,2

– 16,8/23

-20 to +75

-20 to +50

-20 to +75

-20 to +50

400425-117

400425-217

400525-117

400525-217

400425-142

– 400625-242

01

01

02

02

  • Refer to the dimensional drawings on the following page.

SPECIFICATIONS

 

pipe size

 

orifice size

 

flow coefficient Kv

operating pressure differential (bar) 

power coil

(W)

catalogue numberoptions
maintained man. operatorFPMEPDMCR
 

min.

max. (PS)
 

brass

 

stainless steel

air (*)water (*)oil (*)
(mm)(m3/h)(l/min)~=~=~=~=
NC – Normally closed
Rp 3/8162,6430939310,511,2SCE210C093MOVEJ
Rp 1/2163,45709

9

3

3

9

9

3

3

– 9

10,5

16,7

11,2

11,2

SCE210C094MOVEJ
G 1/2SCG210C087MOVEJ
Rp 3/419

16

4,3

3,9

72

65

0

0

9

9

3

3

9

9

3

3

– 9

10,5

16,7

11,2

11,2

SCE210D095MOVEJ
G 3/4SCG210C088MOVEJ
Rp 12511,1

9,6

185

160

0

0

9

9

6

7

9

9

6

7

9

9

6

5

15,4

15,4

23

23

SCE210B154 (3)MOVEJ
G 1SCG210D189VEJ
Rp 1 1/42812,8213096969615,423SCE210B155 (3)MOVEJ
Rp 1 1/23219,3322095959515,423SCE210B156 (3)MOVEJ
NO – Normally open
Rp 3/8162,643099999510,511,2SCE210C033VEJ
Rp 1/2163,4

2,6

57

43

0

0

9

9

9

9

9

9

9

9

9

7

5

5

10,5

10,5

11,2

11,2

SCE210C034VEJ
NPT 1/2SCB210B030VEJ
Rp 3/419

16

4,7

2,6

79

43

0

0

9

9

9

9

9

9

9

9

9

7

5

5

10,5

10,5

11,2

11,2

SCE210C035VEJ
NPT 3/4SCB210B038VEJ
Rp 12511,2185099920SCE210B057 (2)VEJ
Rp 1 1/42812,8213099920SCE210B058 (2)VEJ
Rp 1 1/23219,3322099920SCE210B059 (2)VEJ
  • Mounting position: piping horizontal, solenoid upright.
  • Mounting position, DC only: piping horizontal, solenoid upr